RF2541 BLE4.0 UART Interface-Bluetooth Module

RF2541 BLE4.0 UART Interface-Bluetooth Module

Lora610AES-100mW AES Encrypted Lora Long Range Wireless Transceiver Data Transmission Module

Lora610AES-100mW AES Encrypted Lora Long Range Wireless Transceiver Data Transmission Module

LORA MESH Network RF module-100mW 1W 5W-LoRa-MESH series Mesh network modules

Lora-MESH series are ultra long-distance MESH network data transceiver modules, which adopts the high-performance SX1276/1278 from Semtech. They have NODE and ROUTER working modes, can be as smart repeaters automatically. It is easy to build a network without a blind area or distance limitation. When used as a repeater, just put the module in the area where the signal is weak to extend the range. To avoid interference, Lora-MESH provides 40 frequency channels. Lora-MESH is flexible but easy to use. It comes with many parameters, such as frequency, data rate, output power, Node ID. Users can configure the parameters through a PC or customer’s own device.

₹8,449.00
In stock
SKU
LORA-MESH

Features and Application:

Features:

  • Repeat automatically

  • LORA modulation

  • 40 channels

  • Default 2 bytes Node ID

  • Serial parameters configurable

  • TTL/RS232/RS485/USB for option

  • Max output power: 100mw~5W for option

  • Frequency band: 433/470/868/915Mhz for option

  • Sensitivity up to -139dBm

  • Working temperature: -40 ~ +85 °C

Applications:

  • Robot control

  • Remote control telemetry

  • Industrial data acquisition

  • Wireless data communication

  • Access control system

  • Remote meter reading

  • Security system

  • Home automation

Specification:

Electrical Characteristics:

Functional Description:

Operation

1) Power on Reset

After powered on reset, the TX LED (Red) and RX LED (Blue) will blink 3 times, The total reset time is around 2s.

2) Working Mode

The CS and SET Pin is internally pulled up. Pull CS pin high or leave it open will make modules enter into working mode, the serial and RF are both in receiving mode then.

In NODE working mode, LORA-MESH module stays in receiving mode and wait for the series signal and RF signal.

LORA-MESH module can connect with any device which is the standard 232/485/TTL interface.

  • When the series signal comes, LORA-MESH module will check the input series signal if there is any error, and then transmit the received data out via RF automatically if no errors found.

  • When the RF signal comes, LORA-MESH module will check the input RF signals if there is any error, and then transmit the received data out via series port automatically if no errors found.

  • When one packet is transmitted successfully, the Red LED will blink once.

  • When one packet is received and verified with no problem, the Blue LED will blink once.

(a) Parameter matching

The series parameter between the device and MESH module should be the same, frequencies, channels and RF parameters should be the same in Tx and Rx.

Note: the Default setting is: Baud rate=9600bps,data bit=8,stop bit: 1,parity bit: none。

(b) Delay Time

Data delay exists between series input of the transmitter and series output of the receiver. This Delay Time is different from the series data rate, RF data rate, and payload length.

(c) Package transmission

One packet cannot exceed 56 bytes. LORA-mesh can’t work when the payload length exceeds 56bytes.

3)Router mode

When set as ROUTER, in working mode, LORA-MESH module can repeat the RF signal in the same network automatically to extend the distance.

Normally, Router module is connected with the external power supply to keep a long time in receiving mode and repeat the signal to extend the range.

4)Setting Mode

In working mode, pull low the SET pin to force LORA-MESH module into setting mode. When using the USB bridge board, simply put on the short cap to enter into setting mode.

pin and dimension:

Pin definition:

610:

611:


6100 series:

6102 series:

6103 series:

6500 series:

Mechanical dimension (mm):

610 Dimensions:

611 Dimension:

6100 dimension:

6103 dimension:

6102 series:

6500 series:

FAQ:

A. Why module cannot communicate properly?

1) Check if there is a power connection error;

2) Check if the module is enabled (CS / SET both high);

3) Check if the band, channel, rate, NET ID has set to the same;

4) Check if the module is damaged(light is on?)

B. Why transmission distance is not as far as it should be?

1) Power supply ripple is too large;

2) The antenna types do not match, or not properly installed;

3) The surrounding environment is harsh, strong interference sources;

4) Surrounding co-channel interference;

C. Why receiving data incorrect?

1) Check if the interface compatible with the device;

2) Improper parameter settings.

3) The module data interface is bad.

More Information
Subtitle N/A
UPC/EAN 4604046162164
Count N/A
M.R.P ₹9,998.00
Brand Name CentIoT
Model LORA-MESH
Whoesale Available
Supply Voltage N/A
Dimension N/A
Working voltage range N/A
Data transfer rate N/A
Receiving sensitivity -139 dBm
Maximum output power 100mw~5W for option
Sleep current N/A
Receiving current <20 mA@TTL level ,<30 mA @USB level
Operating Temperature Range -40 ~ +85 °C
Data Rate @LoRaTM 656 bps
Operating Temperature N/A
Frequency 433/470/868/915Mhz
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

No Related Posts